熱門關(guān)鍵詞:蘇瑪罐,原子吸收分光光度計(jì),環(huán)境監(jiān)測產(chǎn)品,液相色譜,色譜柱。
更新時(shí)間:2019-11-14
CarboPac SA10-4μm碳水化合物色譜柱獨(dú)立的單糖的快速生物燃料和食品樣品和更好的分辨率和更容易峰識(shí)別和整合。
免費(fèi)咨詢:010-61755520
獨(dú)立的單糖的快速生物燃料和食品樣品和更好的分辨率和更容易峰識(shí)別和整合。 Thermo Scientific 戴安CARBOPAC?SA10-4μm柱產(chǎn)生比標(biāo)準(zhǔn)戴安CARBOPAC SA10柱高60?80%的峰值效率,從而提供了更好的分辨率和更容易峰鑒定和這些碳水化合物的集成。在4μm的柱分析僅需10分鐘,或者少于8分生物燃料常見的單糖和雙糖的食品樣品中六種常見的糖。
CarboPac SA10-4μm碳水化合物色譜柱
訂貨信息:
Dionex CarboPac SA10-4μm碳水化合物分析柱
分析柱 | |
Dionex CarboPac SA10-4μm Analytical Column (4 x 250 mm) | 088233 |
Dionex CarboPac SA10-4μm Analytical Column (2 x 250 mm) | 088235 |
保護(hù)柱 | |
Dionex CarboPac SA10-4μm Guard Column (4 x 50 mm) | 088234 |
Dionex CarboPac SA10-4μm Guard Column (2 x 50 mm) | 088236 |
Dionex CarboPac SA10-4μm Column for Fast, High-Resolution Mono- and Disaccharide Analysis
The New Thermo Scientific? Dionex? CarboPac? SA10-4μm Column is designed for fast chromatographic analysis of simple sugars in Biofuel and Food samples. The peak efficiencies produced by the Dionex CarboPac SA10-4μm columns produce 60 – 80% higher peak efficiencies than standard Dionex CarboPac SA10 columns, thus producing better resolution and easier peak identification and integration. The Dionex CarboPac SA10-4μm column can analyze six common sugars in Food samples in only 10 min, or eight common Biofuel mono- and disaccharides in less than 8 min.
This is the first in a series of Dionex CarboPac columns that use smaller resin particles. The smaller particles produce more efficient peaks and better resolution making analysis easier and more reliable. The smaller particles also produce higher system back pressure (over 3000 psi) under standard operating conditions and therefore can only be run using Thermo Scientific? Dionex? HPIC? systems such as the Thermo Scientific Dionex ICS-5000+ HPIC system, which can operate up to 5000 psi.
The Dionex CarboPac SA10-4μm column should be used as a direct replacement for the Dionex CarboPac SA10 column only if an HPIC system is available
The polymeric Dionex CarboPac SA10-4μm column is packed with 4 μm supermacroporous substrate, coated with the same strong anion-exchange layer of latex nano beads as the Dionex CarboPac SA10 column, which provides high capacity and rapid, high-resolution separations. The Dionex CarboPac SA10-4μm columns feature high reproducibility, and can withstand thousands of injection cycles under high pH conditions.
Thermo Scientific? Dionex? CarboPac? SA10-4μm Column for Monosaccharide and Disaccharide Analysis Specifications | |
---|---|
Dimensions | Dionex CarboPac SA10-4μm Analytical Column: 4 × 250 mm and 2 × 250 mm Dionex CarboPac SA10-4μm Guard Column: 4 × 50 mm and 2 × 50 mm |
Maximum operating pressure | 5,000 psi (34.5 MPa) |
Temperature range | 4–60 °C |
Typical operating conditions | 4,000 psi at 1.5 mL/min (standard-bore column) or 0.38 mL/min (microbore column) Recommended flow rate: 1.5 mL/min (standard-bore) or 0.38 mL/min (microbore) |
Typical Eluents | Potassium hydroxide via Eluent Generation |
Resin composition | 4-μm diameter sumpermacroporous substrate (ethylvinylbenzene 55% crosslinked with divinylbenzene) agglomerated with 55-nm MicroBead difunctional quaternary ammonium ion (4.5% cross-linked). |
Anion-exchange capacity | Approximately 290 μeq/column (4 × 250 mm standard-bore column) Approximately 73 μeq/column (2 × 250 mm microbore column) |
Column construction | PEEK |